Comparison of diagnostic performances for thyroid cancers among SERA_P, SERA_M, and radiologists
SERA_P | SERA_M | Radiologists | p-value |
p-value |
p-value |
|
---|---|---|---|---|---|---|
Sensitivity | 75 (61.58-88.42) | 85 (73.93-96.07) | 77.5 (64.56-90.44) | 0.091 | 0.739 | 0.361 |
Specificity | 84.93 (80.19-89.67) | 79 (73.6-84.39) | 93.61 (90.37-96.85) | 0.008 | 0.001 | <0.001 |
AUC | 0.8 (0.728-0.872) | 0.82 (0.758-0.882) | 0.856 (0.788-0.923) | 0.526 | 0.163 | 0.414 |
The number in parentheses indicates the 95% confidence interval.
AUC: area under the receiver operating characteristic curve, SERA: Severance Artificial intelligence program, SERA_M: results from SERA using images taken from a mobile phone, SERA_P: results from SERA using images directly downloaded from PACS
*p-value for comparing SERA_P and SERA_M. †p-value for comparing SERA_P and radiologists. ‡p-value for comparing SERA_M and radiologists.